Summary
Coating and drying is one of the critical unit operations in tablet manufacturing. Its
key performance indicators include coating uniformity, tablet mass gain (coating weight
gain), coating efficiency, and tablet temperature and moisture during drying. The
process has to be adjusted for each tablet size and batch size, and physical trials are
costly, slow and generate waste.
Intelimek worked with a pharmaceutical manufacturer to develop an in-silico model that
couples CFD and DEM. It gives process insights that physical trials cannot. Process
engineers used it to analyse bed dynamics for different batch sizes and drum speeds,
coating efficiency and the overall thermodynamics of the coater. This lets them optimise
the process, or adapt it to new requirements, with fewer physical trials.
| Industry | Pharmaceutical manufacturing |
|---|---|
| Process | Film coating and drying in a high-speed, perforated-drum tablet coater |
| Approach | Two-way coupled CFD-DEM, with a custom droplet-based coating module and a drying module |
| Validation | Exhaust air within about 1 °C of the analytical energy balance; total mass balance within 0.3% |
| Key outputs | Fractional surface coverage, tablet mass gain, coating uniformity (RSD), tablet and exhaust temperatures, humidity |
| Compute | About 150 hours on an NVIDIA A100 GPU for 120 s of process time |
| Delivery | Automated web app for non-specialist users |
The challenge
Tablet coaters come in different configurations. Drums run on an RPM profile, in this case on the order of 100 rpm. Some coaters use air knives to break up the tablet ring, and air jets beside the nozzle control the spray spread.
Figure 1: CFD-DEM simulation of the tablet bed inside the rotating drum, with the spray nozzle at the centre. Each tablet is coloured by its coating coverage.
Coating quality depends on several coupled effects: turbulent airflow, spray droplets, heat transfer, solvent evaporation and thousands of colliding tablets. Engineers need answers to practical questions:
Does every tablet receive a
similar amount of coating?
How quickly does the
coating cover each tablet’s surface?
Do tablets get too wet or
too hot, risking defects such as twinning or erosion?
How do air-knife pressure,
airflow and inlet temperature change the outcome?
Most DEM coating studies use a ray-tracing spray model. It projects straight spray paths onto the tablets and records where coating lands. Because droplets arrive instantly and carry no heat or solvent, ray tracing cannot link coating to drying, tablet temperature or exhaust humidity.
Our approach
Intelimek modelled the spray as DEM droplets instead of ray-traced paths, using a custom coating module. The droplets interact with the tablets and the air in a two-way coupled CFD-DEM simulation.
Droplets as particles. Each
spray droplet is tracked in DEM, so it moves with the airflow and can hit tablets or
walls. A run can involve millions of droplets.
Collision detection and
mass transfer. When a droplet hits a tablet, its mass is transferred to that tablet.
Droplets that hit a wall are removed and counted as spray loss. The coating module
was customised to handle this.
Energy balance. Each impact
also transfers the droplet’s energy. The tablet temperature is updated from the
incoming liquid, the hot process air and the heat taken up by evaporation.
Drying module. Solvent
evaporates from the wet tablets into the process air, so drying is part of the same
simulation.
Two-way CFD-DEM coupling.
The air solver and the particle solver exchange momentum, heat and water vapour at
every coupling step, so airflow, tablet motion, coating and drying all affect each
other.
The module also tracks two coating measures per tablet: the coating number, the area the deposited droplets could cover relative to the tablet surface, and the fractional surface coverage, the share of the tablet surface actually reached by droplets.
The main settings are listed below; values are not shown.
| Area | Setting |
|---|---|
| Solvers | Ansys Fluent for air, heat and vapour; Ansys Rocky for tablets and droplets; two-way coupled |
| Flow | Poly hexa-core; cells larger than a tablet in the tablet region; refined at air knives and nozzle |
| Discretisation | Second-order upwind momentum and species, QUICK energy, PRESTO! pressure, least-squares gradients |
| Tablet shape | Actual tablet geometry as a convex polyhedron |
| Drag | Di Felice for tablets; Schiller–Naumann for droplets |
| Heat transfer | Gunn correlation for tablets; Ranz–Marshall for droplets |
| Lift and torque | Neglected; small compared with drag for heavy tablets and small droplets |
| Coupling exchange | Momentum, heat and water vapour every coupling step; DEM time step much smaller than CFD time step |
| Coating measures | Coating number (Kariuki et al., 2013) and fractional surface coverage, per tablet |
Calibration and Benchmarking
Nozzle calibration. The spray nozzle was calibrated so that the model injects the required liquid flow rate with the right spray spread. Droplet size was scaled to keep the droplet count manageable while delivering the same liquid mass.
Analytical benchmarking. The model was checked against an independent steady-state energy and mass balance of the whole coater, using the same inlet flows, temperatures, humidity and spray rate:
The simulated exhaust air
temperature approached the analytical steady-state value and came within about 1 °C
of it.
Total mass balance closed
within 0.3%.
Exhaust humidity stayed at
the inlet value before spraying and rose sharply, by more than 20 times, once the
spray started.
Tablet mass gain stayed
within 6–9% of the analytical value. The analytical value assumes every droplet
lands on a tablet, while the simulation captures droplets lost to the walls and the
air, as happens in the real process
One simulation gives thermal behaviour, coating coverage and coating uniformity together, for every tablet in the batch.
Temperatures. The exhaust air temperature matched the analytical steady state within about 1 °C. The tablet bed stayed 2–4 °C below the exhaust air, as observed experimentally.
Figure 2: exhaust air and average tablet temperature over process time, shown relative to the analytical steady-state exhaust temperature (dashed line, 0). Blue, right axis: exhaust air minus tablet temperature.
Coverage and uniformity. Fractional surface coverage is estimated from the droplet mass added to each tablet and the surface area it can coat. It grew steadily, and the extrapolated time matches the typical coating cycle time of the real process: about 10 minutes for 85% of tablets to be fully covered. Tablet-to-tablet variation in coating mass (RSD) was high just after spraying started, when few tablets had passed through the spray. It fell steadily as tablets cycled through the spray zone, and its trend points to about 14–15% at 10 minutes.
Figure 3: close-up of tablets cascading past the spray nozzle. Tablet colour shows coating coverage (%), from uncoated (light) to most coated (dark).
Figure 4: left, surface coverage reached by 85% of tablets. Right, tablet-to-tablet coating mass RSD, simulated (solid) and extrapolated (dashed).
Comparing process conditions. The model lets engineers compare process conditions, such as drying air flow and air-knife settings, before running trials.
What it takes to compute
The simulation tracks thousands of tablets with their real shape and millions of spherical droplets. Simulating 120 s of the process took about 150 hours on an NVIDIA A100 GPU.
Delivery: A web app for process engineers
Intelimek is packaging the full workflow as a web app for process and formulation engineers who are not CFD or DEM experts. Case setup and the CFD-DEM run are fully automated:
- Select a coater from a library of more than 10 ready-made coater models.
- Select the tablet from a tablet-shape library.
- Set the batch size and configure the nozzles.
- Enter the operating parameters, such as drum speed profile, airflow, air-knife settings, inlet temperature and spray rate.
- Submit. The case is meshed, set up and run automatically.
Results, including interactive 3D visualisation and all coverage, uniformity, temperature and humidity graphs, appear in the same environment.
Takeaway
Tablet coating and drying is a complex process, even to simulate. The model showed promise: it agreed with the analytical benchmark and reproduced patterns observed experimentally. Modelling the spray as droplets, and capturing their interaction with tablets, brought in the thermodynamic coupling between spray and tablets. Because it captures the spray’s interaction with the tablets, it gives more accurate insight than ray tracing into how much spray each tablet receives and the resulting mass gain. Deploying the model as a web app, with automated case setup and CFD-DEM execution, makes it usable by engineers without solver expertise: a significant step towards democratising simulation.
References
- W. I. J. Kariuki, B. Freireich, R. M. Smith, M. Rhodes and K. P. Hapgood, “Distribution nucleation: Quantifying liquid distribution on the particle surface using the dimensionless particle coating number,” Chemical Engineering Science, vol. 92, pp. 134–145, 2013. doi:10.1016/j.ces.2013.01.010
- Altair, “Perform Spray Coating Analysis” (ray-tracing spray coating), EDEM documentation. help.altair.com
- R. Di Felice, “The voidage function for fluid–particle interaction systems,” International Journal of Multiphase Flow, vol. 20, no. 1, pp. 153–159, 1994.
- L. Schiller and A. Naumann, “Über die grundlegenden Berechnungen bei der Schwerkraftaufbereitung,” Zeitschrift des Vereines Deutscher Ingenieure, vol. 77, pp. 318–320, 1933
- D. J. Gunn, “Transfer of heat or mass to particles in fixed and fluidised beds,” International Journal of Heat and Mass Transfer, vol. 21, no. 4, pp. 467–476, 1978.
- W. E. Ranz and W. R. Marshall, “Evaporation from drops,” Chemical Engineering Progress, vol. 48, pp. 141–146 and 173–180, 1952.